You are using an outdated browser Internet Explorer. It does not support some functions of the site.

Recommend that you install one of the following browsers: Firefox, Opera or Chrome.

Contacts:

+7 961 270-60-01
ivdon3@bk.ru

Modern technology to improve the accuracy of implantation of less invasive knee replacement on the basis of mathematical modeling

Abstract

Modern technology to improve the accuracy of implantation of less invasive knee replacement on the basis of mathematical modeling

A.V. Alabut, V.D. Sikilinda, N.B. Klimenko

Incoming article date: 26.02.2013

In order to improve techniques of minimally invasive total knee arthroplasty (IEAC) based on anatomical studies, we have developed a mathematical model and a computer program IEAC preoperative planning that takes into account the anthropometric data of the patient (body type, size patellar index Insall-Salvati), type and size of prosthesis and allows to calculate minimal incision and maximum elongation wound during surgery. Use of this software improves the accuracy of the planning and preparation of surgery, to improve the accuracy of implantation of the prosthesis.

Keywords: minimally invasive replacement of knee joint, computer modelling, preoperative planning, computer software preoperative planning