Determination of the main factors of installation of the gas pollution detector

Abstract

Determination of the main factors of installation of the gas pollution detector

Novohatskaya А.А., Kondaurov Р.Р.

Incoming article date: 19.04.2022

The main recommendations for the installation of a gas pollution detector in domestic premises are considered, an experiment is conducted using the Altair 4x gas analyzer, the purpose of which is to determine the concentration of the gas-air mixture at various points of the household relative gas source. The data obtained experimentally is analyzed, which results in a formula that allows you to determine the approximate concentration of the gas-air mixture, I only know the measurement time and height relative to the ceiling to the measurement point. Also, this formula allows us to note that when choosing the installation location of the gas pollution detector, attention should be paid to the distance from the ceiling to the installation point of the device, while the distance from the wall to the installation site of the device plays a less important role when a gas leak is detected by the device.

Keywords: gas pollution detector, gas-air mixture, gas concentration, emergency shutdown, lower concentration limit of flame propagation