  • Mathematical modeling of heat transfer and hydrodynamics in models of ceramic honeycomb heat exchangers

    Using numerical modeling, we performed studies of the influence of the angle of inclination of the plates of the regenerative heat exchanger element on the heating time and pressure drop. The studies were conducted for models of heat exchange elements with lengths of 6 and 20 mm. Depending on the length of the element, the angle of inclination of the plates was: 10°, 20°, 30°, 40° (at L=6 mm) and 3°, 6°, 9°, 12° (at L=20 mm). At the boundary of the calculation area, the air flow velocity and temperature were established, namely 1 and 3 m/s, and 303 and 973 K. The research results demonstrated that increasing the angle of inclination of the plates helped reduce the heating time of the regenerator by 38.56-49.1%, depending on the length of the heat exchange element, the speed and temperature of the air flow.

    Keywords: heat recovery, honeycomb heat exchanger, numerical modeling, calculation, heating time, pressure drop, heat exchanger geometry, angle of plate, air flow velocity, air flow temperature