  • Evaluation of load-bearing capacity design of baskets for conditioners: analysis of results and tests

    The article presents the results of the laboratory test and finite element modeling of the facade basket design for the outdoor unit of the split system. A comparative analysis of the obtained data is performed. During the modeling, the main possible design situations were taken into account and the perilous zones were determined, in which destruction is expected. To confirm the obtained design values, a full-scale test was carried out, in which wind pressure was modeled using two horizontally applied loads. Based on the test results, it was determined that the modeling method used corresponds to reality, and the nature of destruction and maximum permissible loads were also established. Based on this, a conclusion was made about the suitability of using the facade basket design option considered in the article for the specified operating conditions.

    Keywords: finite element model, testing, load-bearing capacity, reliability, deformability, air conditioner basket, bracket, destruction